Refrigeration Mentor
Канада
Добавлен 8 авг 2014
This channel is focused on creating content that can help as well as entertain Refrigeration & HVAC professionals around the globe. I am going to share refrigeration skills and knowledge with the next generation of industry leaders and those who are looking to grow. From mentoring and goal setting to deep technical learning, my vision is to help 10 million professionals around the world achieve the success they are looking, and help them develop a growth mindset to start taking action.
Disclaimer: All videos are for intended for educational purposes only.
Disclaimer: All videos are for intended for educational purposes only.
Setting Up RDM Transcritical CO2 High Pressure Valve HPV & Flash Gas Bypass Valve (FGBV) Expert Tips
Setting Up RDM Transcritical CO2 High Pressure Valve (HPV) & Flash Gas Bypass Valve (FGBV) | Expert Tips
Description:
Join Trevor Matthews, alongside Chris Prom and Cody Hamm from RDM, as they guide you through the setup process for RDM's Transcritical CO2 High Pressure Valve (HPV) and Flash Gas Bypass Valve (FGBV). In this detailed tutorial, you'll learn step-by-step instructions, best practices, and expert tips to ensure optimal performance and efficiency in your refrigeration systems.
**What You'll Learn:**
- Detailed setup instructions for HPV and FGBV
- Best practices for configuring and optimizing RDM valves
- Troubleshooting common issues
- Expert insights from industry professionals
Wheth...
Description:
Join Trevor Matthews, alongside Chris Prom and Cody Hamm from RDM, as they guide you through the setup process for RDM's Transcritical CO2 High Pressure Valve (HPV) and Flash Gas Bypass Valve (FGBV). In this detailed tutorial, you'll learn step-by-step instructions, best practices, and expert tips to ensure optimal performance and efficiency in your refrigeration systems.
**What You'll Learn:**
- Detailed setup instructions for HPV and FGBV
- Best practices for configuring and optimizing RDM valves
- Troubleshooting common issues
- Expert insights from industry professionals
Wheth...
Просмотров: 364
Видео
CO2 Refrigeration Revolution: Expanding Applications & Embracing Innovation with Scott Martin
Просмотров 1,1 тыс.21 день назад
CO2 Refrigeration Revolution: Expanding Applications & Embracing Innovation with Scott Martin
What are high ambient strategies? | Free CO2 Transcritical Refrigeration Training Part 2
Просмотров 770Месяц назад
What are high ambient strategies? | Free CO2 Transcritical Refrigeration Training Part 2
What are high ambient strategies? | Free CO2 Transcritical Refrigeration Training Part 1
Просмотров 1,1 тыс.2 месяца назад
What are high ambient strategies? | Free CO2 Transcritical Refrigeration Training Part 1
CO2 REFRIGERATION CYCLE BASICS | FREE HVAC TRAINING | HOW A REFRIGERATION SYSTEM WORKS
Просмотров 2,5 тыс.2 месяца назад
CO2 REFRIGERATION CYCLE BASICS | FREE HVAC TRAINING | HOW A REFRIGERATION SYSTEM WORKS
Danielle Wright Interview at the NASRC Natural Refrigerants Training Event
Просмотров 1852 месяца назад
Danielle Wright Interview at the NASRC Natural Refrigerants Training Event
Morgan Smith Interview at NASRC Natural Refrigerants Training Event
Просмотров 1762 месяца назад
Morgan Smith Interview at NASRC Natural Refrigerants Training Event
12 Week Advanced CO2 Transcritical Refrigeration Design and Engineering Training Course
Просмотров 3492 месяца назад
12 Week Advanced CO2 Transcritical Refrigeration Design and Engineering Training Course
How A Refrigeration System Works Thermodynamically Vs System Components
Просмотров 2,1 тыс.4 месяца назад
How A Refrigeration System Works Thermodynamically Vs System Components
Advancements in Refrigeration Technology: Copeland's Premier Components at the 2024 AHR Expo
Просмотров 8655 месяцев назад
Advancements in Refrigeration Technology: Copeland's Premier Components at the 2024 AHR Expo
Sizing and Selecting Transcritical CO2 Compressors
Просмотров 2 тыс.6 месяцев назад
Sizing and Selecting Transcritical CO2 Compressors
Unlock the Secrets of HVACR & Compressor Troubleshooting: A Step-by-Step Guide!
Просмотров 1,4 тыс.7 месяцев назад
Unlock the Secrets of HVACR & Compressor Troubleshooting: A Step-by-Step Guide!
How a Chiller Works with a Magnetic Compressor
Просмотров 1,2 тыс.7 месяцев назад
How a Chiller Works with a Magnetic Compressor
Programing an RDM CO2 Case Controller
Просмотров 1988 месяцев назад
Programing an RDM CO2 Case Controller
Danfoss CO2 System Manager with Patrick Clardy
Просмотров 3828 месяцев назад
Danfoss CO2 System Manager with Patrick Clardy
Controlling a Live CO2 Transcritical System with RDM
Просмотров 4828 месяцев назад
Controlling a Live CO2 Transcritical System with RDM
Danfoss Part 4 - CO2 Heat Recovery System
Просмотров 5658 месяцев назад
Danfoss Part 4 - CO2 Heat Recovery System
RDM Temperature vs SH Case Controller Strategy
Просмотров 1198 месяцев назад
RDM Temperature vs SH Case Controller Strategy
RDM Setting Case Controller Parameters
Просмотров 3758 месяцев назад
RDM Setting Case Controller Parameters
Changing the way its has been done w/ Frascold CEO Mr. Giuseppe Galli
Просмотров 2068 месяцев назад
Changing the way its has been done w/ Frascold CEO Mr. Giuseppe Galli
Unlocking the Potenital of RDM's CO2 Transcritical Rack Controller
Просмотров 1,2 тыс.8 месяцев назад
Unlocking the Potenital of RDM's CO2 Transcritical Rack Controller
Carel pR300T Compressor Rack Controller
Просмотров 5279 месяцев назад
Carel pR300T Compressor Rack Controller
How To Start Up and Commission a CO2 Transcritical Professional Ice Rink Plant
Просмотров 1,3 тыс.9 месяцев назад
How To Start Up and Commission a CO2 Transcritical Professional Ice Rink Plant
The Perfect Oil Level in a Compressor
Просмотров 3,6 тыс.9 месяцев назад
The Perfect Oil Level in a Compressor
Just because you haven't had a blowout doesn't mean you shouldn't release the pressure off the regulator. It's a 5 second process. It's better than your tank turning into a missle literally.
Am working on a scroll compressor that most tech that check unit sed that compressor burn but when I check compressor is working but meaking a lot of noise already have a new one seem like it wos running with out oil foun out that unit have a refrigerant leak from the high side of the unit U tink that can cause unit to stop suction or the discharge pressure from moving up or down
@@hubertjacob9606 that is not enough information. Did you measure the oil out of the old compressor?
@@RefrigerationMentor I can't the compressor is still on condencing unit I add sum poe oil to compressor but compressor still not puming
Does this apply to r22 to 407c for AC? I work with 06Ds in Liebert units and retrofit r22 systems to 407c a lot. I never took into account the operation envelope of the compressors.
Yo Trevor, got a question I went back to the appliance field from HVAC and was wondering if it's an issue that I use my huge Field Piece pump (the first gen with replacable oil while pulling a vacuum) for domestic refrigerators?
@@natepeterson7145 no it’s not an issue but it won’t save you any more time then a smaller pump, as i use to think. Bigger pump = faster evacuation is not the case with smaller systems.
@@RefrigerationMentor just making sure my over sized pump isn't sucking out the oil. These hydrocarbon refrigerators discharge lines get stupid hot. So much you can hold onto them for a while. Thanks for the reply!
Hi Trevor, whats the tool to tighten the packing with the two slots cut on each side. That one you cannot put a wrench on.
Very little vibration
@@johnpaulsonjr7214 nailed it. Thanks for commenting.
learned this at school and it makes a world of difference! That and temp. control
@@teemowins4017 awesome. Sounds like you had some good teachers. Share more of your knowledge with others. It sounds like you have a lot.
Hi trevs how do i clean a restriction from a under conter fridge.do i clean like im cleaning a domestic fridge using a R22a ?
@@bennimotlatsi8901 can you elaborate
Hi there, in the case the ice rink hall would be elevated over the ground, with floors under for parking and storage, could the refrigerating plant be located in the floor right under the ice field? thanks in advance for any input!
@@lluhu yes but it would have to be designed and engineered correctly.
@@RefrigerationMentor many thanks!
All that safety gear, but no safety glasses??? 😂😂😂
The best mentor ever
thankssss my costumer is really scaredddd!!! hehehe
That seal is what fails prematurely on these, i only got 4 yesrs before failing
how do you check discharge superheat
would love to know more
Single phase scroll compressor don't really need a start capacitor.
Whoever that Troll is that keeps popping up from the bottom of your screen is distracting! Can we get _rid_ of him?! He’s popped up six times already and we’re not even half way through the presentation. I _know_ you’re not _that_ desperate! MAKE IT STOP!! Ok, I was wrong. Apparently you _are_that desperate. 0:27; 1:27; 1:53; 2:44; 3:28; 4:09; 4:58; 5:43; 6:24; 7:15; 7:59; 8:41; 9:22; 10:06; 10:47; 10:39; 12:22; 13:03; 13:53; 14:13
Cool infomercial
How do I get ahold of this free guide?
@@Jway8412 offers.refrigerationmentor.com/free-guide?
@RefrigerationMentor Thank you so much for what you do. You have helped me tremendously. I'm listening to all your podcasts and looking into taking your supermarket master class. Keep up the awesome work brother!
I rebuild various compressors for a living the amount of compressors I inspect that are seized and come back to the workshop with no oil is amazing, faulty oil regulators that are never tested or checked just reset constantly.
@@Kritchley I believe it. Too many compressors are replaced without the proper checks
Very good information, I'm not a supermarket tech but I work with semi hermetic compressors a lot.
Think about the poor bastard who has to come behind and repair the system. So many times, I've had to stand on my head, remove parts of a system to get to what I really need to work on, or shut down large parts of a system because of no isolation valves when often a little more thought than "what would be the easiest way to install this" would go a long way.
I love it when oil is discombobulating for no reason
Your wrong! Ill do it wrong many times
Awesome
Great information Trevor, thanks for sharing.
@@PaulNoreen thanks for watching. I appreciate the comments.
I ASK YOU TO PLEASE ADD TURKISH SUBTITLES TO THE SUBTITLES OF YOUR VIDEOS. WE CANNOT BENEFIT FROM YOUR VIDEOS.
All of our compressors we have have a low pressure safety switch connected at the port on the crank case that you pointed at. With that being said, what is the best way to take the pressure in the crank case? Is there an alternative? Thanks.
@@Jway8412 that is a great question. You have two options add a tee fitting or take it off pressure off the suction. I would just take it off the suction unless you get a bad reading or need to do a blow by test.
@@RefrigerationMentor great info! Thanks for the reply 👍
My gentilin c330 is overheating not sure y
I just replaced the sentronic to a coresense and have no LED at the module. Do I need a wire on terminal 2 as a neutral? 115 vac
@@LibertyMurph check the coresense manual and find the wiring schematic. You have to add a 3rd wire to power it at all times. And if you have demand cooling or a digital compressor connected you will have different wiring again. Check the manual.
Look at logs to see if happening at certain tkmes. See if system dumping into header at compressor locatiin . Sentronic sensor on reciprocal compressor plugged. Bad contactor sticking causing over amp and opening internal w😅😊windings then timing out on oil control. Oil filter plugged. Suction filters left in after start up causing oil return issues. Too small oil reservoir and all compressors coming on after a defrost statving oil supply y825 oil differential bad. Oil check valve top of resevoir bad. Valve plate bad. If scroll oil level control inlet screen plugged. I could go on and on. Thats only half of it. Not enough info given.😊
“Your technicians”
Your oil leak is something else.
@@dbell41888 yes it definitely could be.
Valve plates
Are those classes online ?
@@nakiapringley5391 we have many. Head to www.refrigerationmentor.com to learn more.
Compressors #1 and #2 is overflowing with oil, but compressors 4 and 5 don't get enough. Is the oil getting past the separator and coming back through the suction?
@@chris84662 that could be one of many things. Compressor staging, plugged screens, floodback, defrost issues, piping issues. It is Very hard to say with this information. Check the pressure diff across the separator and the temp of each compressor discharge line.
How does that look is my question. As a new tech.
@@dioncurtiscurtis3188 learn as much as you can as fast as you can. Investing in yourself by taking refrigeration courses on your own, going to events, calling manufactures for help and taking more on calls.
@@dioncurtiscurtis3188 lots of great content at www.refrigerationmentor.com
Never worked with Bitzer, only with Dorin
@@Rollerguitar96 they make great compressor too. Check out the video I did with Dorin on my CO2 playlist
@@RefrigerationMentor i sure will have a look into it :-)!
Vapour can also condense in the accumulator on off cycle , makes it look like a flood start
@@VoiD1x very true. Refrigerant will travel to the coldest part of the system.
Brilliant video, what could be causing the system to go out on HP? Apart from it being a blocked gas cooler?
@@adamdart855 overcharged, air in the system, fan setup, HPV programming, FGBV issues. There are many other things that could cause issues.
You made those words up. And used Ai to make fake images
No I have not
@@michaels3757 hopefully it is helpful
The company better be supplying that stuff. If they don’t then it sounds like it’s time to drag up.
13psi is not 0.7b but nearer 0.9b. Also, Temprite separators will pop the bottom seal, which could rule out pressure difference check.
@@blokefromsmoke you are right. I made a mistake. 13 psi is .896 bar. Thanks for noticing.
❤
Thanks bro God bless you I wish u the best you are good hearted
wouter is absolutely correct